414 |
  Selektivni mjerač polja
Narda SRM-3006 | Laboratorija za mjerenje nivoa elektromagnetnih emisija | 1 | 2011 | 2012 | Laboratorija za mjerenje nivoa elektromagnetnih emisija
| Dimensions:213 x 297x 77 mm (basic unit)
Weight with antenna: 3300 g
Color display: TFT-LCD 7 inch, 800 x 480 pixels
Frequency range: 9 kHz to 6 GHz
Temperature range: -10° to +50° C
Battery operating time: 3 hours +/- 15 minutes Mjerenje nivoa električnog polja | ||
86 |
  Microscope
AMSCOPE ZM-1TW3-FOD-5M | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 2023€ | Elektrotehnički fakultet
Tadić Nikša | Head: 360 degree rotatable 45 degree inclined trinocular
• Eyepiece: 30mm super widefield high-eyepoint WH10X/22MM & WH25X/9MM
• Zoom Range: 0.2X-22.5X
• Diopter Adjustment: +/- 5dp
• Interpupillary Distance: 2-3/16" - 2-15/16"(55-75mm)
• Working Distance: 14" (350mm)
• Field of View: 5-3/4" (145mm) in diameter
• Stand: 12.5"x10"x0.75" (320mm x 260mm x 20mm) solid cast steel base | ||
85 |
  ELISA plate washer
Allsheng APW-100 | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 3462,90€ | Biotehnički fakultet
Latinović Nedeljko | For 96-well microplates
Suitable for flat, U, V, C bottom
Including 3 bottles and tubings | ||
84 |
  ELISA microplate reader
Allsheng AMR-100 | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 4510,10€ | Biotehnički fakultet
Latinović Nedeljko | Wavelength: 340 to 750 nm | ||
82 |
  CHN analyzer
Leco 628 Series Elemental Determinators | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 74000€ | Biotehnički fakultet
Topalović Ana | Carbon, Hydrogen, Nitrogen determination in macro samples
Instrument principle of operation – Dumas combustion method
The analyzer is able to analyze from few miligrams up to minimum 0.25 g weight of samples for CHN in organic materials
C: 0,02 – 175 mg
H: 0,1 – 12mg
N: 0,04 – 50 mg
up to 1050 °C | ||
81 |
  Multi place stir/hot plate 4 place
THERMO SCIENTIFIC SUPER-NUOVA MULTI POSITION | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 2905€ | Institut za biologiju mora
Joksimović Aleksandar | Four independently controlled heating/stirring positions, ceramic top and 4-function memory | ||
80 |
  pH Meter
XS PH50 | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 532€ | Institut za biologiju mora
Joksimović Aleksandar | pH Range: ≤ 0.00 to ≥ 14.00
Resolution: pH – 0.01
Accuracy: ± 0.01 pH + 1 LSD (two decimal digits)
Temperature Compensation: Automatic/Manual (0 to 100°C)
Automatic calibration 1 to 3 points | ||
79 |
  Balance
KERN EW2200-NM | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 672€ | Institut za biologiju mora
Joksimović Aleksandar | Capacity max: 2200 g.
Readability: 0.01 g. Tare facility. Digital Display
Stainless Steel Weighing pan: rectangular, dimensions 180 mm x 160 mm.
Automatic setting. Weighing range in grams. Precision + 0,01 g. | ||
78 |
  Code surface drifter
METOCEAN CODE/DAVIS ARGO DRIFTER | BIO-ICT | 6 | 2016 | 2016 BIO-ICT 3964€ | Institut za biologiju mora
Joksimović Aleksandar | Operation Conditions
Air Temperature: -20° C to +35° C
Water Temperature: -2° C to +35° C
Water Type: Fresh or Salt
Significant Wave Height: 8.0 m / 26 ft
Wind Speed: 20 m/s / 40 knots
Wind Gusts: 30 m/s / 60 knots
External Humidity: 100% (external)
Sunlight: Direct Exposure
Operating Life: 3-12 months depending on sampling
Shelf Life: 24 months with storage conditions at ~21° C
Survival Conditions
Air Temperature: -30° C to 35° C
Water Temperature: -2° C to 35° C
Significant Wave Height: 12.0 m / 40 ft
Wind Speed (at 10m): 35 m/s / 70 knots
Electronics
Iridium Transceiver: 9602 SBD
Antenna: Low Profile Dual Band
Iridium/GPS
Power Supply: 10 Alkaline-manganese dioxide D-cells
Sensors
Sea Surface Temperature: US Sensor ±.05° C Thermistor
Battery Voltage: Precision Resistive Divider
GPS Receiver: Jupiter F2 | ||
77 |
  Centrifuge
HETTICH UNIVERSAL 320R | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 8285€ | Institut za biologiju mora
Joksimović Aleksandar | 200-240V, 50-60Hz refrigerated bench-top centrifuge without rotor, 1 pcs
Angle-rotor 6x85 ml, 1 piece – (code HT 1620A ref brochure)
Reducing-part, 1-place, size 2, for tubes of 15 ml, 17x100 mm, 6 piece
Reducing-part, 1-place, size 2, 6 piece for tubes of 50 ml, 34x100 mm
Reducing part, 1-place, size 2, 6 piece for Falcon tubes of 15 ml, 17x120 mm,
Reducing-part, 1-place, size 2, 6 piece for Falcon tubes of 50 ml, 29x115 mm
Tube 15 ml, 17 x 100 mm, 15 piece cylindrical, graduated
Tube 50 ml 34 x 100 mm, 15 piece cylindrical, ungraduated
Tube 15 ml, conical, graduated, plastic PP, with screw cap, 500 piece
Tube 50 ml, conical, graduated, plastic PP, with screw cap, 500 piece | ||
76 |
  Fume Cupboards
ASAL COMBI 1200 | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 10692€ | Institut za biologiju mora
Joksimović Aleksandar | Overall dimension w x d x h: 1280 x 780 x 1540 mm
The housing sides: closed
The worktops: gres monolithic
The underbench cabinet: acid & base unit
The exhaust air socket; the monitor/controller for air, The lighting, two-piece panel made of laminated safety glass; Cold water tap; electrical sockets; Main fan unit with 5 mm PVC pipes | ||
75 |
  Milli-Q Water Purification System
MERCK/MILLIPORE MILLI-Q Reference | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 9077€ | Institut za biologiju mora
Joksimović Aleksandar | Resistivity 18.2 MΩ.cm at 25 °C
TOC ≤ 5 ppb (μg/L)
Bacteria < 0.1 cfu/mL
Pyrogens (endotoxins) < 0.001 Eu/mL (pyrogen-free)
RNases < 0.01 ng/mL (RNase-free)
DNases < 4 pg/mL (DNase-free) | ||
71 |
  Automated line for preparation and pouring of culture media and solutions
Bio-Merieux MASTERCLAVE 09 + AUTOMATED FILLER XY500+VC MYLA SYSTEM | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 45783,46€ | Institut za javno zdravlje
Vratnica Zoran | 1) MASTERCLAVE 09 Automated system for the preparation of culture media and solutions
- Capacity: 1 - 9 liters
- sterilization temperature: 95 - 125°
- Sterilization time: 1 to 60 minutes
- Security cover: cannot be opened at a temperature > 80° C
- filling temperature: 25 to 80° C, with an accuracy of +/- 1° C
- magnetic stirrer
- permanent monitoring of the selected program cycles and temperature, as well as their printing
- the possibility of storing 30 fully customizable programs
- the possibility of the introduction of new protocols and manual programming
- the possibility for connecting system to PC
- ticket printer kit
2) APS ONE Automated system for pouring in Petri dishes (Ø90mm and Ø55mm) with stacker
Capacity: 560 Petri dish
- Filling speed: 700 Petri dish per hour (volume of 14 ml per plate)
- "Easy load" peristaltic pump and three silicone tubing systems
- Aditional Twin Pump Head peristaltic pump (for addition of blood)
- Cooling system
- UV lamp active during pouring process
- Dispended volume of 1 to 50 ml per Petri dish
- Dispended volume of 1 to 1000 ml (for manual filling of containers of various - flasks, test tubes, petri dish ...)
- Inkjet printer for Petri dishes
3) XY500 + PM i Automated system for filling of tubes, bottles, etc.
- High precision peristaltic pump
- accuracy and a repeatability compliant with ISO 7218, ISO 6887-1 & ISO 16189
- Distribution mode: Single-dose, Multi-dose
- Adjustable speed
- Various diameters of ready-to-use tubing sets
- Program management: Cycle, speed, number of doses, delay between each dose
- Positioning repeatability > 99% | ||
70 |
  MALDI-TOF mass spectrometry system for microbiology
Bio-Merieux Vitek MS Plus | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 186168,11€ | Institut za javno zdravlje
Vratnica Zoran | 1) MALDI-TOF instrument
• Capacity: 192 samples per run, 4 slides x 48 tests.
Possible of preparing and reading several slides at the same time;
- fully automated sample injection, power and targeting laser control software;
- linear flow tube length > 1,2 m,
- mass resolution > 5000 FWHM-ACTH 18-39 ((M + H) + 2465 Da),
- mass range 1 - 500 kDa,
- accuracy 30 ppm,
- ability to access search engines on the Internet and intranet database for identification of proteins,
2) Preparation station for the preparation and registration of data of the sample, which is via software transmitted directly to the instrument
• Computer with barcode scanner, which is connected via USB directly to the relevant hardware;
• The possibility of additional preparatory stations at different positions, which are not in the same room with the instrument;
• Possibility of integrated sample preparation for MALDI-TOF ID and automated determination of susceptibility testing.
3) The station for collection and compilation of data
• Computer with barcode scanner;
• Directly connected with the instrument, receives the raw data, processes them, and provides insight into the range (spectrum);
• The possibility of a unified analysis of samples for MALDI-TOF ID and automated determination of antimicrobial susceptibility testing.
4) Software
• Base IVD with at least 580 clinical types, 13,000 isolates, 25,000 spectrum (average 20 strains / species, average 40 spectrum / type);
• The possibility of parallel use of research (Non IVD) database, which should covers at least 1200 species / genera, 9,500 isolates (reference strains), 18,000 spectrum, (average 8 strains / species, average 15spectrum / types);
• Creating of superspectra and analysis of dendrograms;
• Computer application - middleware, based on web technology, which enables monitoring of related work processes in the laboratory, compatible with laboratory information system, with a central server and multi-user access;
• A software connection of existing automated systems in microbiology laboratory;
• The possibility of reporting patient results and statistical and epidemiological monitoring of the results. | ||
69 |
  HPLC
Shimadzu Nexera XR | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 35500€ | Institut za biologiju mora
Joksimović Danijela | Flow precision: ≤0.06% RSD or ≤0.02 min SD
Flow accuracy: ± 1% or better
Flow setting range: 0,0001– 5.0000 ml/min in 0.0001 ml/min increments
Operating pressure range: 0 – 660 bar
Solvent Capacity: quaternary valve system LPGE
Number of mixed solvents: 5
Gradient accuracy: maximum +/- 0,5 full scale
Seal wash: automatic
Bottles for mobile phase, filters, tubing | ||
68 |
  Microwave owen
Anton Paar MULTIWAVE PRO | BIO-ICT | 2 | 2016 | 2016 BIO-ICT 27000€ po komadu | Institut za bioligiju mora (1 komad)
Institut za javno zdravlje (1 komad)
| High microwave power that provides fast vessel heating
Unpulsed microwave emission
Homogeneous microwave distribution throughout the cavity
Maximum safety through pressure-responsive door
All stainless-steel construction
Fast vessel cooling through powerful air flow system
Installed microwave power up to 1.700 watts
Microwave cavity entirely made of 18/8 stainless steel housing with multi-layer PTFE plasma coating applied at over 350°C.
All hardware protected against acids/organic solvents with polymer coating both on inside and outside surfaces.
Micro-switches of which minimum 3 safety interlocks to prevent microwave emission with door open.
Exhaust located separate from electronics to prevent corrosion.
Graphic display of all, individual sample temperate, and pressures in real time.
Patented non-contact IR temperature measurement, (precision +/- 1 C at 300°C)
Internal memory for data records and full document – 128 Mbyte of DDR SDRAM (32bit), 1 Gbyte of NAND FLASH (8 Bit)
Direct temperature monitor and control up to 310°C in a reference vessel
Direct pressure monitor and control up to 115 bar in a reference vessel
Touch-screen user interface 9” TFT-LCD screen
VGA resolution 800x480 pixel | ||
67 |
  Atomic absorption spectrophotometer
Shimadzu AA-7000 | BIO-ICT | 1 | 2016 | 2016 BIO-ICT 22000€ | Institut za biologiju mora
Joksimović Danijela | Wavelength range 185 – 900 nm.
Computer controlled wavelength selection; automatic slit 0.2, 0.7, 1.3, 2.0L nm (4-step automatic switching).
6-lamp turret, 2 lamps simultaneously lit (1 for measurement, 1 warming up for next measurement).
Automatic lamp position optimisation,
Supplied with Air/acetylene burner, Nitrous oxide/acetylene burner
Automatic gas control, Automatic fuel gas flow rate setting (0.1 L/min step)
Automatic search of optimum gas flow rate
• Automatic gas leak check
• Automatic Air-N2O switching as C2H2 flow rate increases
• Flame monitor
• Prevention of wrong burner head use
• Gas pressure monitor
• Drain tank level monitor
• Automatic flame extinction upon power outage or sudden power interruption
• Automatic flame extinction via flame vibration sensor
• Flashback detection
• Internal fan stop sensor
Separate ignite and flame off buttons
Lamp for Mn, Fe, Pb, Cd, Zn, Ni, Cr, Cu,Co.
Supplied with Hollow cathode lamps for As, Hg, Se, Sn.
Vapour generation accessory including:
• Pump unit
• AA hydride module
• Cell holder to fit air/acetylene burner
• Reagent containers
• All tubing, hoses and connectors
• Quartz cell
Software:
• Windows compatible software for data acquisition and processing, and for control of all instrument parameters via a PC
• Quantification and Calibration
• Data import and export to other software
• Possibility to upgrade the system for new instruments | ||
60 |
  Analizator električne energije
Dranetz POWER GUIDE 4400 | 1 | 2004 Projekat 6875$ | Laboratorija za EES
| |||||
59 |
  Mjerač otpora izolacije
Megger S1-5005 | 1 | 2004 Projekat 5187€ | Laboratorija za EES
| |||||
58 |
  Generator funkcija
Tektronix AFG3021 | 1 | 2008 | 2008 Tempus projekat 1883€ | Laboratorija za primijenjenu elektroniku
| ||||
57 |
  Analizator spektra
Agilent N1996A | 1 | 2008 | 2008 Tempus projekat 8571€ | Laboratorija za primijenjenu elektroniku
| ||||
56 |
  Osciloskop
Tektronix DPO4104 | 1 | 2008 | 2008 Tempus projekat 13920€ | Laboratorija za primijenjenu elektroniku
| ||||
55 |
  Osciloskop
Agilent U1640A | 1 | 2008 | 2008 Tempus projekat 1312€ | Laboratorija za primijenjenu elektroniku
| ||||
54 |
  Osciloskop
Agilent MSO6012A | 1 | 2008 | 2008 Tempus projekat 5019€ | Laboratorija za primijenjenu elektroniku
| ||||
53 |
  Osciloskop
Agilent DSO3120A | 10 | 2008 | 2008 Tempus projekat 1029€ | Laboratorija za primijenjenu elektroniku
| ||||
52 |
  LCR metar
Instek LCR-827 | 1 | 2008 | 2008 Tempus projekat 1696€ | Laboratorija za primijenjenu elektroniku
| ||||
51 |
  WARP MIMO kit
WARP MIMO kit | ICT istraživački centar | 2 | 2013 | 2014 ForeMont projekat (FP7) 4915€ | ForeMont research center - Elektrotehnički fakultet
Pejanović Đurišić Milica | WARP FPGA Board
WARP Clock Board
Two WARP Radio Boards
Two 2.4GHz antennas
Two 5GHz antennas | ||
50 |
  Open Flow Switch
Pica PRONTO 3290 | ICT istraživački centar | 1 | 2013 | 2014 ForeMont projekat (FP7) 2775€ | ForeMont research center - Elektrotehnički fakultet
Radusinović Igor | Supports OpenFlow
48 10/100/1000BASE-T RJ45 ports
4 10Gbps SFP+ uplink ports
2 10/100/1000BASE-T management ports
1 serial management port - 115.200 Baud rate
Forwarding modes: Store-and-forward
Bandwidth: 176Gbps
Switch latency: less than 40us for 64-bytes frames (nonblocking)
Packet buffer embedded in switch chip: 4MB+ | ||
49 |
  Workstation
Apple Imac | ICT istraživački centar | 12 | 2013 | 2013 ForeMont projekat (FP7) 2188€ | ForeMont research center - Elektrotehnički fakultet
Pejanović Đurišić Milica | Processor 3,1GHz Quad-Core Intel i7, 16GB DDR3 (1600MHz) RAM, 1TB HDD, special graphics processor with dedicated memory, 21.5-inch diagonal display with a resolution of minimum 1920×1080, Gigabit Ethernet, 4xUSB 3.0, Thunderbolt port, Bluetooth 4.0, Wireless 802.11n, built-in videoconferencing camera, keyboard, mouse, operating system Mac OS X (Mountain Lion) - preinstalled + Windows 8 Professional 64bit. | ||
48 |
  PreBuilt NetFPGA platform
Accent | ICT istraživački centar | 1 | 2013 | 2014 ForeMont projekat (FP7) 1470€ | ForeMont research center - Elektrotehnički fakultet
Radusinović Igor | AMD Athlon II X2 260 dual core; 2048MB RAM;
250GB SATA HDD; DVD RW; NetFPGA Board; Cube Design case;
Dual Port 1Gb/s NIC. | ||
47 |
  Universal Counter
Agilent 53220A | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 2060€ | ForeMont research center - Elektrotehnički fakultet
Radonjić Milutin | Frequency range up to 350MHz,
12 digits/s, time interval resolution 100ps,
Interface: LAN, USB, GPIB | ||
46 |
  Function Generator
Agilent 33500B | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 1570€ | ForeMont research center - Elektrotehnički fakultet
Radonjić Milutin | 1-Channel up to 30 MHz sine, square and pulse signal waveforms,
250 MSa/s, 16-bit sampling rate
USB and LAN Interface | ||
45 |
  Server
Hewlett Packard HP DL360p | ICT istraživački centar | 2 | 2013 | 2013 ForeMont projekat (FP7) 4540€ | CIS
| Intel Xeon 6 core processor 2,9GHz, 32GB RAM, 2x2TB HDD, 2x1TB HDD, 4xEthernet port, DVD-ROM, Redundant power supply | ||
44 |
  Rack Cabinet
Hewlett Packard HP BW904A | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 2605€ | CIS
| 42U Standard 19" Rack Cabinet, Cooling system with thermostat,
230 Volt 6 Outlet Power Distribution Unit
48 modules patch panel with Ethernet RJ-45 Cat 6 modules
Horizontal Cable Manager 2U | ||
43 |
  Workstation
Hewlett Packard HPZ620 | ICT istraživački centar | 4 | 2013 | 2013 ForeMont projekat (FP7) 3878€ | ForeMont research center - Elektrotehnički fakultet
Radusinović Igor | 2x Intel Xeon 6-core processor at 2,5GHz, 16 GB RAM 1333MHz DDR3 ECC, 2TB HDD, DVD-R/RW, Integrated Ethernet port + AMT, single port Ethernet adapter, dual port Ethernet adapter.
HP ProDisplay P221 TFT Monitor HD resolution (1920x1080) LED backlight
Keyboard + optical mouse | ||
42 |
  Electric And Magnetic Isotropic Field Analyzer
Maschek ESM-100 | Laboratorija za mjerenje nivoa elektromagnetnih emisija | 1 | 2013 | 2013 ForeMont projekat (FP7) 5000€ | Laboratorija za mjerenje nivoa elektromagnetnih emisija
Radusinović Igor | Frequency range: 5 Hz to 400 kHz
Measurement range: 0.1V/m to 100kV/m, 1nT to 20mT
Acquisition method: Simultaneous three-axis acquisition
Internal data logger up to 24h
Control and application software | ||
41 |
  Oscilloscope
Agilent MSOX 3104A | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 10735€ | ForeMont research center - Elektrotehnički fakultet
Radonjić Milutin | 1 GHz, 5 GS/s, 4 analog/16 digital channels | ||
40 |
  Optical Time Domain Reflectometer (OTDR)
Senter ST 3300-C | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 2400€ | ForeMont research center - Elektrotehnički fakultet
Veljović Zoran | Wavelengths: 1310nm/1550nm
Dynamic range: 30/32dB | ||
39 |
  Fusion Splicer
Senter AV6471 | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 3000€ | ForeMont research center - Elektrotehnički fakultet
Veljović Zoran | Applicable fiber: SMF(ITU-T G.652), MMF(ITU-T G.651), DSF(ITU-T G.653), NZDSF
Average splicing loss: 0.02dB(SM), 0.01dB(MM), 0.04dB(DS), 0.04dB(NZDS)
Align mode: Advanced PAS align mode Povezivanje optičkih kablova | ||
38 |
  Multiservice Tester
Bluelight BL 400A | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 5300€ | ForeMont research center - Elektrotehnički fakultet
Radusinović Igor | Multiservice tester enable testing of info-communication infrastructures and services such as: Carrier Ethernet, MPLS L2/L3 VPNs, Multicast and Triple Play services.
The tester is able to generate traffic and perform appropriate analysis.
Throughput testing, Generate multi stream traffic up to 1Gbit/s line rate on copper and optical multi-ports, Ethernet frames, IP packets layer 1/2/3/4 with multiple modes such as continuous, ramping, burst mode.
Packet analysis such as FCS errors, L3/L4 checksum errors, Round Trip Delay (RTD), Packet Arrival Interval (PAI), packet loss, sequence errors.
Ports:
2 optical SFP 1000 BASE-SX/LX/ZX and 100 FX
2 copper 10/100/1000 BASE-T
Auxiliary RJ45 10/100 Mbit/s Ethernet port
Multiple testing capability
Ethernet test, VoIP test
Fiber channel test (1x, 2x, 4x)
Performance measurement (Traffic Generation/Throughput Test)
Filtering, IP Tools (Ping, DHCP, Trace Route), Real time in-line monitoring
Ethernet OAM/ Loopback (Layer 1/2/3/4), Framed bit error test (BERT)
RFC 2544 (Network equipment benchmarking test)
Cable faults measurement (copper and optic cables)
Remote operation file management, Reporting (ASCII, CSV, and PDF) | ||
37 |
  Signal Analyzer
Aeroflex 3252 | ICT istraživački centar | 1 | 2013 | 2014 ForeMont projekat (FP7) 20000€ | ForeMont research center - Elektrotehnički fakultet
Veljović Zoran | Frequency range: 1 kHz - 8 GHz
30 MHz analysis bandwidth,
Basic EMI pre compliance measurement capability available, including CISPR 16-1-1 bandwidths, detectors, amplitude correction factor, band preset, tune & listen at marker, and limit lines, LXI class C compliant, USB 2.0, 1000Base-T LAN, GPIB interface
Flexible digital modulation analysis measurement application
Analog demodulation measurement application | ||
36 |
  Test set
ZTEC ZT8201, ZT 8651, ZT 8751 | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 60000€ | ForeMont research center - Elektrotehnički fakultet
Pejanović Đurišić Milica | Vector signal generator frequency range: 250MHz – 6GHz
RF output: +20 to -80dBm
Modulation bandwidth: 500MHz
Differential baseband output: DC-200MHz
Vector signal analyzer frequency range: 250MHz – 6GHz
RF input: +20 to -120dBm
Analysis bandwidth 160MHz
Differential baseband inputs: DC-300MHz
Software for creation and protocol analysis capability
For 802.11ac through AC/160MHz
Create reference signals: LTE, HSPA+ WiMAX, WLAN, DVB-H, DAB, MATLAB and more Appropriate software for generating 3GPP
W-CDMA signals which can be connected to vector signal generator | ||
35 |
  Vektor signal generator
Stanford Research Systems SG 396 | ICT istraživački centar | 1 | 2013 | 2013 ForeMont projekat (FP7) 18000€ | ForeMont research center - Elektrotehnički fakultet
Veljović Zoran | Frequency range: DC to 6.075 GHz
Frequency resolution: 1 µHz
Analog modulation: AM, FM, ΦM, Pulse, Sweeps
Dual baseband generator for I/Q modulation
Digital I/O, MIMO fading and RF to RF fading
Data types: PRBS, pattern, user
Vector Modulation: PSK (including BPSK, QPSK, OQPSK, π/4DQPSK, 8PSK, and 16PSK), QAM (4-256), FSK, CPM (1 – 4 bits), MSK, ASK, VSB
Digital filters: Nyquist, root Nyquist, Gaussian, rectangular, linear, sinc, user FIR Telekomunikacije |